3. Select the PC ComPort where the iPort is connected to your
computer.
4. Use the Options menu to override default Baud Rate and I
2
C
Bus Clock rate settings.
5. Establish a link to the iPort with the Open button. The iPort
Message Center software sets the iPort’s own I
2
C Slave
address to 0xFE.
6. To open an existing message list, click File|Open List on the
menu bar. To enter or edit a message List, open the “I
2
C
Message Editor” screen, by double clicking on a message row
in the spreadsheet.
Now you can:
a. Set the I
2
C address (i.e. 4C, 4E, etc.)
b. Set Msg Direction (Read or Write)
c. Do stop (yes or no, Repeated starts)
d. Set time delay (delay in msec, controls speed of activity).
e. Write message data (from 00 to FF) or read count.
f. Click OK.
Repeat above steps for additional messages.